Epidermal Electronic Tattoos & Stretchable Biocompatible Electrodes in Athletic Base Layers: Dry-Contact EMG/ECG Recording, Siloxane Encapsulation, and Motion-Artifact Filtering - Sports Outlines Sialkot Manufacturer

Epidermal Electronic Tattoos & Stretchable Biocompatible Electrodes in Athletic Base Layers: Dry-Contact EMG/ECG Recording, Siloxane Encapsulation, and Motion-Artifact Filtering

In the clinical realm of cardiology and neurology, capturing human biopotential signals—specifically electrocardiography (ECG) for cardiac rhythm and electromyography (EMG) for skeletal muscle activation—has traditionally relied on disposable silver/silver-chloride ($\text{Ag/AgCl}$) pre-gelled wet electrodes. While these clinical patches provide excellent low-impedance electrical contact in stationary hospital environments, they are fundamentally incompatible with high-intensity athletic training. Wet electrolytic gels dry out within two to three hours of ambient exposure, degrade under turbulent sweat flow, cause contact dermatitis and skin maceration during multi-hour workouts, and peel loose under vigorous bodily motion.

To liberate athletes from messy adhesive gels and rigid electrode plates, wearable bio-electronics and technical apparel engineering have converged on epidermal electronic tattoos (E-tattoos) and stretchable dry-contact electrodes integrated directly into athletic base layers. Engineered with ultrathin, skin-conforming serpentine conductive traces and breathable siloxane encapsulation, these dry biopotential nodes achieve hospital-grade electrophysiological recording directly through natural skin contact. When laminated onto compression athletic apparel, epidermal electrodes eliminate motion artifacts, conform to microscopic dermal ridges, and survive continuous athletic flexing ($\varepsilon > 60\%$) without electrical discontinuity. At Sports Outlines, operating our high-performance apparel manufacturing and technical prototyping facility in Sialkot, Pakistan, we combine serpentine fractal conductive patterning, liquid metal circuits, biomedical silicone encapsulation, and precision compression garment assembly. We provide performance apparel brands, sports science institutions, and medical telemetry labels with physical prototype sampling at $45 to $85 per piece (non-refundable, 7–10 business days turnaround) and scalable commercial apparel production starting at a low factory minimum order quantity (MOQ) of just 30 to 50 pieces per style/colorway.

Epidermal Biopotential Electronics in Sportswear: Technical Navigation Directory

1. Electrophysiology of Biopotentials: ECG P-Q-R-S-T Waves & EMG Motor Unit Action Potentials

Human biopotential signals originate from the depolarization and repolarization of excitable cellular membranes in cardiac and skeletal muscle tissue. In clinical monitoring and athletic telemetry, smart base layers target two primary biopotential signatures:

  • Electrocardiography (ECG): Represents the synchronized electrical activity of the myocardium. The signal comprises the P-wave (atrial depolarization), the Q-R-S complex (ventricular depolarization, generating the dominant $0.5\text{ to }3.0\text{ mV}$ peak at frequency bandwidths between $0.05\text{ and }150\text{ Hz}$), and the T-wave (ventricular repolarization). In endurance athletics, high-fidelity ECG capture allows algorithms to calculate heart rate variability (HRV), autonomic nervous system balance (RMSSD), and ischemic ST-segment shifts in real time.
  • Electromyography (EMG): Captures the spatial and temporal summation of Motor Unit Action Potentials (MUAPs) generated across contracting skeletal muscle fibers. Surface EMG signals exhibit micro-volt amplitudes ($50\ \mu\text{V to }5.0\text{ mV}$) across a broad frequency spectrum ($10\text{ to }500\text{ Hz}$, peaking around $50\text{ to }150\text{ Hz}$). Real-time EMG analysis enables athletic trainers to evaluate instantaneous neuromuscular firing rates, inter-muscular coordination, eccentric vs concentric load distribution, and the precise onset of neuromuscular fatigue through median frequency (MDF) spectral shifts.

2. The Skin-Electrode Interface: Stratum Corneum Impedance & Equivalent Circuit Models

The primary engineering barrier in capturing micro-volt biopotentials without wet chemical gels is the human stratum corneum. The stratum corneum is the outermost layer of the epidermis, comprising 15 to 20 layers of flattened, dead keratinized corneocytes embedded in a hydrophobic lipid matrix. Mechanically rugged and electrically insulating, dry stratum corneum exhibits a massive electrical impedance ($|Z| > 500\text{ k}\Omega\text{ to }1.5\text{ M}\Omega\cdot\text{cm}^2$ at $10\text{ Hz}$).

The electrical behavior of the skin-electrode interface is modeled via an expanded Randles equivalent circuit:

Z_{interface}(\omega) = R_s + \frac{R_{ct}}{1 + j\omega R_{ct} C_{dl}} + \frac{R_{sc}}{1 + j\omega R_{sc} C_{sc}}

Where $R_s$ represents the bulk resistance of underlying dermal tissue and perspiration electrolytes; $R_{ct}$ and $C_{dl}$ represent the charge-transfer resistance and electrical double-layer capacitance at the conductive electrode boundary; and $R_{sc}$ and $C_{sc}$ characterize the parallel resistance and dielectric capacitance of the dry stratum corneum.

In traditional rigid metal electrodes, microscopic air gaps between the rigid planar disc and the microscopic valleys of human dermatoglyphics (skin furrows, depth $20\text{ to }100\ \mu\text{m}$) cause $C_{dl}$ to plummet and $R_{ct}$ to skyrocket, introducing severe signal attenuation. In contrast, epidermal electronic tattoos possess an ultra-low bending stiffness ($D < 10^{-7}\text{ N}\cdot\text{m}$), allowing the flexible conductive sheet to deform seamlessly into skin wrinkles, establishing conformal intimate contact that slashes interfacial impedance to less than $25\text{ to }45\text{ k}\Omega\cdot\text{cm}^2$ at $50\text{ Hz}$ without needing a drop of electrolyte gel.

3. Dry-Contact Nanomaterials: CNT-PDMS Composites, Liquid Metals & Gold Nanomeshes

To deliver continuous bio-potential conductivity while matching the elastomeric mechanics of human skin (Young’s modulus $E_{skin} \approx 100\text{ to }500\text{ kPa}$), materials scientists have developed three cutting-edge nanomaterial systems for smart activewear base layers:

  • Carbon Nanotube-Polydimethylsiloxane (CNT-PDMS) Composites: Multi-walled carbon nanotubes (MWCNTs, diameter 10–20 nm, length 20–50 µm) are dispersed at $5\text{ to }8\text{ wt}\%$ within a low-modulus silicone matrix. The high aspect ratio of the nanotubes forms a dense 3D conductive percolation network ($\sigma > 150\text{ S/cm}$). The silicone base provides elastomeric mechanical softness ($E \approx 350\text{ kPa}$) and natural skin tackiness that adheres gently without chemical glues. Micro-texturing the CNT-PDMS surface with inverse pyramid micro-structures ($10\ \mu\text{m}$ pitch) enhances effective contact area by 280%, stabilizing contact impedance during intense athletic motion.
  • Eutectic Gallium-Indium (EGaIn) Liquid Metal Networks: At room temperature, EGaIn ($75.5\%\text{ Ga}, 24.5\%\text{ In}$) is a true liquid metal with metallic electrical conductivity ($\sigma \approx 3.4 \times 10^4\text{ S/cm}$) and theoretical infinite fatigue life. EGaIn forms a self-passivating native gallium oxide ($\text{Ga}_2\text{O}_3$, thickness $\approx 1\text{ to }3\text{ nm}$) skin that stabilizes liquid tracks during direct-ink-writing (DIW) printing ($\pm 10\ \mu\text{m}$ resolution). When encapsulated within elastic siloxanes, liquid metal interconnects maintain virtually constant electrical resistance ($\Delta R/R_0 < 1.05$) under extreme tensile stretching exceeding $250\%$, eliminating signal dropouts during explosive athletic movements.
  • Ultra-Flexible Gold/Titanium Nanomeshes: Thermally evaporated gold (thickness 50–100 nm, primed with 5 nm titanium adhesion layers) on a sacrificial biocompatible polymer mesh. The open-mesh geometry provides exceptional gas and sweat permeability ($WVTR > 24,000\text{ g/m}^2\cdot 24\text{h}$), completely preventing sweat accumulation or skin irritation during prolonged multi-day wear.

4. Serpentine & Fractal Mechanics: Peano Curves, Horseshoe Meshes & Strain Relief

Solid metallic thin films fracture and lose electrical continuity at minute tensile strains ($\varepsilon < 1.5\%$). To enable thin-film metallic electrodes to stretch and bend alongside elastomeric activewear fabrics ($\varepsilon > 40\%\text{ to }60\%$), smart apparel engineers utilize serpentine and space-filling fractal geometry.

By patterning conductive traces into periodic horseshoe arches, Peano space-filling curves, or deterministic Koch fractals, macroscopic axial tensile strain is absorbed through out-of-plane buckling and in-plane bending of the serpentine ribbons rather than physical stretching of the metal crystal lattice:

\varepsilon_{elastic\_limit} = \pi^2 \cdot \left(\frac{w}{2 R}\right) \cdot f(\theta_0) \gg \varepsilon_{bulk\_metal}

Where $w$ is the ribbon width ($25\text{ to }50\ \mu\text{m}$), $R$ is the arc radius, and $\theta_0$ is the subtended arc angle (typically $180^\circ\text{ to }220^\circ$). In self-similar Peano curves with fractal dimension $D = 2.0$, local bending strain energy is uniformly distributed across thousands of microscopic hinges. Under rigorous finite element analysis (FEA) and cyclic stretching validation, these serpentine fractal meshes sustain continuous athletic elongation up to $\varepsilon = 70\%$ with less than $1.8\%$ electrical resistance drift ($\Delta R/R_0$), enduring $>50,000$ expansion cycles without mechanical micro-cracking or localized stress concentration.

5. Siloxane Encapsulation: Breathability, Sweat Vapor Transmission & Dielectric Isolation

Biopotential lead traces traveling from the electrode sites to the telemetry processing hub must be electrically isolated from the external environment. Perspiration is an electrolytic saline solution; if uninsulated conductive traces are wetted by sweat, electrical short-circuits and crosstalk across adjacent EMG channels will instantly corrupt the diagnostic data.

We protect our epidermal circuit nodes using micro-molded biomedical poly(dimethylsiloxane) (PDMS) and polyether TPU siloxane hybrid coatings:

  • High Dielectric Breakdown Strength: Siloxane encapsulation films ($25\ \mu\text{m}$ thick) provide dielectric breakdown voltages exceeding $20\text{ kV/mm}$, preventing inter-channel capacitive coupling and cross-talk during intense sweating.
  • Micro-Porous Vapor Permeability: Laser-perforated breathing micropores ($50\ \mu\text{m}$ diameter, pitch $400\ \mu\text{m}$) allow insensible cutaneous water vapor to escape ($WVTR > 12,000\text{ g/m}^2\cdot 24\text{h}$), eliminating skin wrinkling and contact dermatitis while maintaining hermetic liquid-barrier isolation over the active conductors.
  • Low Elastic Modulus Matching: Modulus calibrated to $E \approx 400\text{ kPa}$ ensures zero mechanical peeling or pulling sensation against delicate skin during explosive athletic sprints.

6. Motion Artifact Filtering: Active Differential Amplification, CMRR & RLD Drivers

In ambulatory sports tracking, the greatest threat to signal integrity is motion artifacts. When an athlete runs, jumps, or swings a racket, mechanical vibration and fabric sliding alter the skin-electrode contact area. This physical deformation modulates the double-layer capacitance ($C_{dl}$), generating high-amplitude, low-frequency voltage spikes ($10\text{ to }100\text{ mV}$ at $0.1\text{ to }5\text{ Hz}$) that swamp micro-volt biopotential signals.

Our smart base layer architecture neutralizes motion artifacts through a synergistic tripartite hardware-software defense:

  1. Ultra-High Common-Mode Rejection Ratio (CMRR): Biopotential signals are recorded differentially ($V_{out} = A_d (V^+ – V^-)$) using medical-grade instrumentation amplifiers (e.g., Texas Instruments ADS1298) delivering a $\text{CMRR} > 115\text{ dB}$ at $50/60\text{ Hz}$. Low-noise programmable gain amplifiers (PGA) amplify tiny micro-volt signals with an ultra-low input-referred noise floor ($<1.0\ \mu\text{V}_{\text{RMS}}$ from 0.1 to 150 Hz), preserving clean physiological signals.
  2. Active Right-Leg Drive (RLD) Inversion: A third feedback electrode samples the body’s common-mode electrical noise, inverts the signal $180^\circ$ out-of-phase, and drives it back onto the skin, actively canceling electrostatic interference from overhead lighting and athletic gym equipment.
  3. High-Q Notch Filters & 24-Bit Sigma-Delta ADC: Powerline interference is attenuated via digital twin-T notch filters ($50\text{ Hz}$ or $60\text{ Hz}$ with quality factor $Q > 30$). High-resolution 24-bit analog-to-digital converters oversample signals at 8 kHz before decimation, capturing subtle ECG fragmentation and high-frequency EMG firing dynamics.
  4. Real-Time Adaptive Wavelet Filtering: Digital signal processors (DSP) inside the detachable telemetry pod apply stationary wavelet transforms (SWT, Symlet-4 wavelets) and Butterworth high-pass filters ($0.5\text{ Hz}$ cutoff for ECG, $20\text{ Hz}$ for EMG) to strip baseline wander and electrode sliding artifacts without distorting clinical QRS peak morphology or muscle firing envelopes.

7. Comparative Matrix: Dry-Contact Textile Electrodes vs Wet Ag/AgCl vs Metal Studs

The technical matrix below compares electrical, mechanical, biocompatible, and manufacturing metrics across three primary electrode paradigms in sports biometrics:

Engineering PropertyEpidermal E-Tattoos (Dry Nanomesh)Clinical Wet Ag/AgCl Gel PatchesStainless Steel Snap Studs
Electrolytic Gel RequirementZero (100% Dry Contact)Mandatory Conductive HydrogelRequires Water / Sweat Wetting
Contact Impedance @ 50 Hz25 to 45 kΩ·cm² (Conformal)5 to 15 kΩ·cm² (Initial Wet)>350 kΩ·cm² (Poor Conformance)
Operational Lifespan per SessionUnlimited (>24 Hours Stable)2 to 4 Hours (Gel Dehydration)Unlimited (Severe Chafing)
Mechanical Stretchability>60% (Serpentine Fractals)<5% (Rigid Polymer Disc)0% (Rigid Solid Metal)
Motion Artifact SensitivityUltra-Low (Shear-Tolerant)Moderate (Peels Under Heavy Sweat)Extreme (Severe Sliding Artifacts)
Laundering Longevity50+ Machine Wash CyclesSingle-Use Disposable Patch30 Cycles (Corrosion & Rust Risk)
Garment Integration ProfileSub-Millimeter Hot-Melt FilmExternal Adhesive StickingBulky Metal Stud Riveting

8. Anatomical Placement: SENIAM Surface EMG Mapping & Einthoven ECG Vectors

In high-performance sportswear manufacturing, precision electrode placement dictates biopotential signal quality. Placing an electrode even 15 mm off the target muscle belly drastically degrades signal-to-noise ratio due to inter-muscular crosstalk. Our design blueprints adhere strictly to international clinical standards:

  • Surface EMG Placement (SENIAM Protocol): For athletic compression tights and performance tops, electrode pairs are mapped to the midline of the muscle belly, aligned parallel to muscle fiber pennation angles:

    • Quadriceps (Rectus Femoris & Vastus Lateralis): Centered at 50% on the line connecting the anterior superior iliac spine (ASIS) to the superior patella. Evaluates explosive leg drive in sprinters and cyclists.
    • Hamstrings (Biceps Femoris): Mapped along the posterior thigh to detect hamstring strain risk and asymmetry during maximum velocity sprinting.
    • Gluteus Maximus & Medius: Tracks pelvic stability and glute activation during squats, Olympic lifts, and endurance running.
  • ECG Placement (Modified Einthoven Lead I & Lead II): In compression tops and sports bras, electrode pairs are integrated across the sub-pectoral line (V1/V2 and V5/V6 equivalents) along the 4th and 5th intercostal spaces. This configuration maximizes R-peak amplitude ($>1.5\text{ mV}$) while minimizing pectoralis muscle contraction artifacts during push-ups, rowing, and barbell bench pressing.

9. Compression Mechanical Coupling: 18 to 25 mmHg Pressure & Dermal Conformance

Dry electrodes rely entirely on mechanical intimacy to displace microscopic air gaps at the skin interface. At Sports Outlines, our biomechanical garment patterns enforce calibrated graduated compression of 18 to 25 mmHg across all electrode zones.

Engineered with high-modulus warp-knit fabrics (75% Polyamide 6.6 / 25% Spandex, 260 GSM), this compression window achieves the optimal physiological sweet spot:

  • Zero Air Gap Maintenance: Compression pressures exceeding $15\text{ mmHg}$ force the flexible siloxane electrode into skin micro-crevices, stabilizing double-layer capacitance ($C_{dl}$) and eliminating 95% of baseline motion wander.
  • Preserved Capillary Perfusion: Pressures are kept strictly below $28\text{ mmHg}$, ensuring arterial blood flow and capillary micro-circulation are never restricted, preventing athlete discomfort or premature muscle fatigue.

10. Textile Lamination: Hot-Melt Polyurethane Bonding & Stretchable Silver Busbars

Routing biopotential signals from the chest or thigh to a centralized waist-mounted telemetry hub requires stretchable, low-resistance wiring conduits. We eliminate conventional copper wiring harnesses in favor of screen-printed stretchable silver/polyurethane conductive buses:

  1. Screen Printing of Serpentine Traces: Formulated using sub-micron silver flakes dispersed in an elastomeric PU binder ($R_s < 0.15\ \Omega/\text{sq}$), printed in sinusoidal meander tracks directly onto release carriers. The meander geometry enforces an amplitude-to-wavelength ratio ($A/\lambda = 0.65$) that redirects tensile elongation into torsional twisting, keeping internal metallic shear strains below 0.8% even when the garment stretches over 50%.
  2. Hot-Melt TPU Encapsulation Lamination: The silver busbars are sandwiched between two layers of aliphatic polyether TPU adhesive film ($50\ \mu\text{m}$ thick) and thermally fused onto the base layer fabric at 135°C under 3.5 bar pressure for 18 seconds. This thermoplastic weld fully encapsulates the conductor within an elastomeric matrix that prevents moisture penetration and cyclic fatigue cracking.
  3. Anisotropic Conductive Film (ACF) Interconnects: At the interface between flexible printed conductive traces and rigid electronic components, thermosetting Anisotropic Conductive Films (ACF with 5 µm conductive nickel-gold polymer spheres) are thermocompression bonded at 180°C under 2.0 MPa pressure. ACF delivers micro-ohm contact resistance ($R_c < 15\text{ m}\Omega$) while maintaining high electrical insulation between adjacent 0.5 mm pitch traces.
  4. Hermetic Snap Docking Interface: Gold-plated magnetic pogo-pin headers or ultra-low-profile molded snaps terminate the busbars, providing an IP67 waterproof junction for the rechargeable BLE telemetry pod.

11. Durability Testing: Cyclic Stretching (ISO 7854) & Laundering Fastness (AATCC 135)

Smart biometric apparel must endure harsh commercial laundering and extreme athletic distortion without losing diagnostic accuracy:

Sports Outlines Epidermal Biometric Base Layer QA Testing Standards

  • Cyclic Flex Fatigue (ISO 7854 Method C): Endures 50,000 continuous flex cycles at 50% strain with less than $3.5\%$ change in electrical bus resistance.
  • Laundering Durability (AATCC 135 / ISO 6330): Tested through 50 machine wash cycles at 40°C with standard athletic detergents. The waterproof TPU-siloxane seal prevents detergent water ingress, maintaining electrode contact impedance $<50\text{ k}\Omega\cdot\text{cm}^2$.
  • Hydrolytic Stability & Sweat Immersion (ISO 105-E04): Immersed in artificial acidic (pH 5.5) and alkaline (pH 8.0) perspiration solutions for 48 hours at 37°C with zero galvanic oxidation or conductive film breakdown.
  • Martindale Surface Abrasion (ISO 12947-2): Dry electrode skin-contacting surfaces endure >25,000 abrasion rubs at 9 kPa with zero delamination or conductive flake loss.

12. Sialkot Manufacturing: Cleanroom Laser Patterning & Precision Flatlock Assembly

At our Sialkot manufacturing plant, the production of smart biometric base layers combines micro-electronic assembly with master cut-and-sew garment manufacturing:

  1. Laser Cutting of Compression Panels: Computer-controlled multi-ply CO2 lasers slice anatomical garment panels with sub-millimeter precision, ensuring compression gradients align perfectly with SENIAM muscle coordinates.
  2. Pneumatic Heat-Press Lamination: Multi-zone heated pneumatic presses fuse the stretchable electrode networks and siloxane encapsulation layers simultaneously, eliminating manual gluing.
  3. 4-Needle 6-Thread Flatlock Sewing: Yamato flatlock machines integrate conductive wiring tunnels along ergonomic panel seams, enclosing all conductors in soft micro-fiber threads that eliminate skin chafing.

13. Low-MOQ Sourcing & Commercial Factory Terms

Commercializing clinical-grade biometric smart activewear historically required millions of dollars in venture backing and overseas production commitments of 5,000+ units. At Sports Outlines, our specialized prototyping laboratory and agile manufacturing infrastructure in Sialkot democratize smart apparel innovation:

Sports Outlines Commercial Production Terms & Sourcing Terms

  • Low Factory Minimum Order Quantity (MOQ): Strictly 30 to 50 pieces per style/colorway, with flexible size grading across XS, S, M, L, XL, 2XL, and 3XL.
  • Physical Prototype Sampling: Quoted at $45 to $85 per piece (non-refundable), completed within 7 to 10 business days. Prototypes verify dry contact impedance, ECG/EMG signal-to-noise ratio, compression fit, and washing resistance.
  • Client-Furnished CAD Tech Packs: Clients provide finalized design artwork, POM measurements, and electrode placement specs; our engineering staff optimizes circuit routing and snap docking.
  • Complete OEM/ODM Production: In-house screen-printed circuits, siloxane encapsulation, flatlock stitching, and custom silicone branding.
  • Global Express Air Delivery: 3 to 5 business days door-to-door transit to the USA, UK, Australia, Canada, and Europe via DHL/FedEx.

Explore Our Global Manufacturing Silos & Product Portfolios

We manufacture and export compliant technical activewear across major global markets:

Related Smart Textile Guides:

Ready to Develop Epidermal Biometric Smart Sportswear for Your Brand?

Consult with our smart textile engineering team in Sialkot. From dry-contact EMG/ECG electrode lamination and siloxane encapsulation to rapid 7–10 day physical prototyping, we deliver dependable wearable innovation at accessible 30–50 piece MOQs.

14. Frequently Asked Questions (Technical Sourcing FAQ)

Q1: What are epidermal electronic tattoos and how do they function without wet conductive gels?

Epidermal electronic tattoos are ultrathin, stretchable conductive electrodes engineered from nanomaterial composites (such as CNT-PDMS or gold nanomeshes) patterned with serpentine fractal geometry. Because of their ultrathin profile and low bending stiffness, they conform microscopically to the natural ridges and furrows of human skin. This intimate conformal contact slashes interfacial impedance to 25–45 kΩ·cm² without requiring electrolytic gels, providing stable dry biopotential recording.

Q2: How does the system eliminate motion artifacts during vigorous athletic movement?

Motion artifacts are minimized through a combination of mechanical and electronic defenses: calibrated 18–25 mmHg anatomical compression fabric panels that hold electrodes flush against muscle bellies; differential instrumentation amplifiers with CMRR >115 dB; active Right-Leg Drive (RLD) noise cancellation; and real-time digital wavelet filtering that strips baseline wander.

Q3: Can garments with integrated epidermal electrodes be laundered normally?

Yes. The serpentine wiring traces and dry electrodes are hermetically encapsulated within waterproof biomedical polyether TPU and siloxanes, enduring over 50 domestic machine wash cycles at 40°C (AATCC 135). The wireless electronic telemetry pod detaches via magnetic snaps prior to washing.

Q4: What physiological metrics can be tracked using these smart base layers?

The garments continuously record high-resolution electrocardiography (ECG) for heart rate, HRV, and cardiac arrhythmia screening, as well as multi-channel surface electromyography (EMG) across quadriceps, hamstrings, and glutes to evaluate muscle activation intensity, left/right bilateral balance, and neuromuscular fatigue onset.

Q5: What are the sample turnaround time and factory MOQ terms for biometric activewear?

Physical prototype sampling is quoted at $45 to $85 per piece under a strict non-refundable policy, with an expedited completion turnaround of 7 to 10 business days. Commercial production starts at a low factory minimum order quantity of just 30 to 50 pieces per style/colorway, supporting custom size grading from XS to 3XL.

Leave a Reply